Work Station of Solar Hot Water Heater w/Pump, 220V. This listing includes: 1 unit of work station for hot water heating system. Suitable for Split and Pressure system, which set the flow control, heat cycle, the exhaust, pressure control, temperature display, the transfer liquid injection / discharge, etc. Such multi-functional in one compact package of components, it have the features of easy-to-use and installation, its material and operating characteristics to take into account long time of collector in high temperature and other characteristics of the system.
Dimension:420mm 280mm155mm(not include the pipe connection). Pressure of safety valve: 6 bar. Display range of pressure gauge: 0-10bar.Connection to expansion vessel: G1/2 male thread. Flow meter measuring range: 0.1-20L/min. One Sensor for collectorpt1000, probe500 Cel.
Two Sensors for tank NTC10K, B3950 sensor (135oC, PVC cable 105oC). Can be support Normal Pump. Can be support High Efficiency pump.Functions operation and parameters setup (user grade) 1 THET Timing heating. 2 CIRC DHW water circulation function 3 tCYC Tempeature or time setting for DHW pump in three time sections Functions operation and parameter setup (engineer grade) 1. DT Temperature difference for solar circuit pump 2. EMOF Maximum switch-off temperature of collector (for collector emergency close function) 3. CMX Maximum limited temperature of collector (collector cooling function) 4.
CMN Low temperature protection of collector 5. CFR frost protection temperature of collector 6. SMX Maximum temperature of tank 7.
REC Recooling temperature of tank 8. F Switch between Celsius and Fahrenheit. DVWG Anti legionnaires' function 2.
P1 Pump P1 operation mode selection 3. DTS Standard temperature difference of pump (for speed adjustment). RIS Gain for circulation pump (speed adjusting). Pump P2 operation mode selection. FTYP Flow meter type selection.
MEDT Type of heat transfer liquid. MED% Concentration of heat transfer liquid. TSTP Pump interval run-off time. TRUN Pump interval run-on time. AHO /AHF Automatic thermostat function.
BYPR Bypass function (high temperature). LOAD Recovery to factory set. ON/OFF Controller switch on/off button. If there's an exception, we will inform you. (It is impossible to drawback the evaluation). E care our valued customers. Please give us the opportunity to resolve a problem. We understand the concerns and frustrations you might have and try our best to resolve the issues. We are specialized on Energy Saving electronics: Solar water heater and controllers, pump stations, solar charge controller, inverter, SOLAR Lamps, etc.. Please add me to your list of favorite sellers and visit often. We are pleased to work with you! All communication is handled through emails. We strive to answer all emails as quickly as possible. Thank you in advance for your patience. The item "Work Station of Solar Hot Water Heater withPump, 220V" is in sale since Tuesday, June 18, 2013. This item is in the category "Home & Garden\Home Improvement\Heating, Cooling & Air\Water Heaters\Standard Water Heaters". The seller is "mingsi06" and is located in Jiaxing, zhejiang. This item can be shipped worldwide.